Ami tegnap az élre juttatott, az ma már nem elég.
Kizárólag a folyamatos fejlődés tart versenyben
Amiről nincs információd, azt nem tudod kontrollálni! Szűntetsd meg a bizonytalanságot, használd a marginális előnyöket, biztosítsd a rendszeres teljesítmény-monitoringot, elemezd az adatokat és hozz tudatos döntéseket a siker érdekében!


PORTABLE · FIELD TESTING
A VOII egy teljes értékű metabolikus analizátor
Segítségével akár versenykörülmények között, nagy pontossággal monitorozhatod kardiometabolikus adaptációdat. Ismerd meg és használd a benned rejlő potenciált!
FREEDOM TO MOVE
An ergometer can't reproduce water, wind, terrain or race tactics. VOII measures the athlete in the boat, on the bike and on the road – under the conditions the result has to hold up in.
Test where the
performance happens.
Breath by breath.
Measured, not modelled.
SENSORS
ACCURACY
Flow, gas concentrations and ambient conditions are sampled in the sensor unit on the mask and corrected before they reach the screen.
1 - FLOW
+ / - 700 SLM
In and out every breath
2 - GAS
+O2 and CO2
Expired fractions 30 times / secound
3 - AMBIENT
Pressure -Humidity - Temp
Logged with every test
4 - CORRECTION
BTPS
Volumes and body conditions.
RESULT
Breath by breath volumes
VE, VO2, VCO2, RER, CHO, FAT...
SOFTWARE
Decide on site.
Analyse in depth.
Everything you expect from a lab system, in a workflow built for testing away from the lab.
Live view
Gas exchange, O2 pulse and heart rate against the protocol, with the key values on large tiles you can read from a distance.

-
Effort bars against predicted maxima
-
Maximal-effort criteria checked as you go
-
Stage progress and next load change
Checked on the 9-12 panel plots
Accept a suggestion with one click or move it by hand. The markers update across all nine panels, and the training zones follow.
-
Averaging by breaths or seconds, with outlier filtering shown
-
Range values you can lock and carry into the report
-
Predicted HRmax, VO2max and MVV as guide lines

The software suggests.
You decide.

Thresholds from several methods
VT1 and VT2 are suggested from the median of V-slope, ventilatory equivalents and end-tidal pressures. Each method is shown, so you see where they agree – and where they don't.
OUR PRINCIPLE
No estimates.
No modelling.
No AI-generated data.
Suggestions are always shown with the data behind them, and every one can be overruled.
The expert has the last word
Honest about the scope
VOII is not a medical device. It is not suitable for diagnosing, monitoring or treating disease, and is intended for sports, fitness and wellness purposes only.






